Instructions |
1. |
R-134a liquid refrigerant is highly volatile. A drop on the skin of
your hand could result in localized frostbite. When handling the refrigerant,
be sure to wear gloves.
|
2. |
It is standard practice to wear goggles or glasses to protect your eyes,
and gloves to protect your hands. If refrigerant splashes into your
eyes, immediately wash them with clean water.
|
3. |
The R-134a container is highly pressurized. Never leave it in a hot
place, and check if storage temperature is below 52 °C (126 °F)
|
4. |
An electronic leak detector should be used to check the system for refrigerant
leakage. Bear in mind that the R-134a, upon coming into contact with
flame, produces phosgene, a highly toxic gas.
|
5. |
Use only recommended lubricant for R-134a systems. If lubricants other
than the recommended one are used, system failure may occur.
|
6. |
PAG lubricant absorbs moisture from the atmosphere at a rapid rate,
therefore the following precautions must be observed:
|
7. |
If an accidental discharge in the system occurs, ventilate the work
area before resuming the service.
|
1. |
Never cut off or loosen a connection before discharging the system.
|
2. |
Seal the open fittings of components with a cap or plug immediately
to prevent intrusion of moisture or dust.
|
3. |
Do not remove the sealing caps from a replacement component until it
is ready to be installed.
|
4. |
Before connecting an open fitting, always install a new sealing ring.
Coat the fitting and seal with refrigerant oil before making the connection.
|
1. |
When it is necessary to open the refrigeration system, have everything
you will need to service the system ready so the system will not be
left open any longer than necessary.
|
2. |
Cap or plug all lines and fittings as soon as they are opened to prevent
entrance of dirt and moisture.
|
3. |
All lines and components in parts stock should be capped or sealed until
they are ready to be used.
|
4. |
Never attempt to rebind formed lines to fit. Use the correct line for
the installation.
|
5. |
All tools, including refrigerant dispensing manifold, gauge set manifold
and test hoses, should be kept clean and dry.
|
Hyundai Creta GS 2014-2024 Service Manual: Specifications
Specifications
Item
Specifications
Transaxle type
A6GF1
Engine type
Gasoline 1.6MPI
Torque converter type
3-element, 1-stage, 2-phase type
Torque converter ...
Hyundai Creta GS 2014-2024 Service Manual: Cylinder Head Cover
Components and components location
Components
1. Cylinder head cover
2. Cylinder head cover gasket
Repair procedures
Removal
1.
Remove the engine cover.
(Refer to Engine And Transaxle Assembly - "Engine ...